A-70
Intrepid® 6140 Director Installation and Service Manual
Event Code Tables
Event Code: 810
Message: High temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP card indicates the warm temperature threshold was reached or
exceeded.
Action: Replace the indicated CTP card with a functional card. Perform the data collection procedure and return the CD
and faulty card to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error
Indicator
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 811
Message: Critically hot temperature warning (CTP card thermal sensor).
Severity: Major.
Explanation: The thermal sensor associated with a CTP card indicates the hot temperature threshold was reached or
exceeded.
Action: Replace the indicated CTP card with a functional card. Perform the data collection procedure and return the CD
and faulty card to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED