Power Supply Events (200 through 299)
A-27
Event Code Tables
Event Code: 202
Message: Power supply thermal failure.
Severity: Major.
Explanation: The thermal sensor associated with a power supply indicates an overheat condition that shut down the power
supply. The second power supply assumes the full operating load for the director.
Action: Replace the failed power supply. Perform the data collection procedure and return the CD and failed power
supply to McDATA support personnel.
Event Data: No supplementary data included with this event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident
Event Code: 203
Message: Power supply AC voltage recovery.
Severity: Informational.
Explanation: AC voltage recovered for the power supply. Both power supplies adjust to share operating load for the director.
Action: No action required.
Event Data: No supplementary data included with the event.
Distribution: Director Management Server Host
Nonvolatile
System
Event Log
System
Error LED
Event Log E-Mail Call-Home Sense Info Link Incident