McDATA OPENconnectors Command Line Interace Instrukcja Użytkownika Strona 82

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 406
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 81
2
2-38
E/OS Command Line Interface User Manual
config
Output This command displays the BB_Credit data:
Output Example
Config.Port> showCredits
Pool Total Allocated Available Ports
------ ----- --------- --------- -----
Pool 1 252 190 62 0-3,8-11,16-19,24-27
Pool 2 252 80 172 4-7,12-15,20-23,28-31
or
Config.Port> showCredits
Pool Total Allocated Available Ports
------ ----- --------- --------- -----
Pool 1 150 100 50 0-23
config.port.speed
Syntax speed portNumber portSpeed
Purpose This command sets the speed for a port.
This command will be available always, but the CLI will respond
with an error if the hardware supports only one link speed. In order
to change a port speed to 2Gb/sec, the switch speed must be
configured to 2Gb/sec.
Pool The BB_Credit pool. Possible values:
Sphereon 4300 – Pool 0
Sphereon 4400 – Pool 0
Sphereon 4500 – Pool 0
Sphereon 4700 – Pool 0 and Pool 1
Total The total number of BB_Credits that this pool
contains.
Allocated The number of BB_Credits that are currently
allocated to ports.
Available The number of BB_Credits that are currently
available to allocate to ports.
Ports A list of port numbers that belong to the pool.
Przeglądanie stron 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 405 406

Komentarze do niniejszej Instrukcji

Brak uwag